Resistance to fire

Laws and classifications

The old Italian MI.SA. Circular No. 91 of 14 September 1961 has now been superseded by the Ministerial Decree of 16 February 2007 “Classification of fire resistance of products and construction elements in building works” and by the Ministerial Decree of 9 March 2007 ‘Fire resistance performance of buildings in activities subject to the supervision of the National Fire Brigade’ and the subsequent Ministerial Decree of 3 August 2015, the Fire Prevention Code, which has completely revolutionised active and passive fire protection. The framework standard is EN 13501-2 “Fire classification of construction products and elements – Part 2: Classification based on the results of fire resistance tests, excluding ventilation systems”. This standard covers all load-bearing and non-load-bearing structural elements, such as walls, beams, floor slabs, columns, suspended ceilings, paints, plasters, raised floors, fire doors, external façades, etc. The relevant Eurocode standard is EN 199x-1-7 “Design of structures made of steel, concrete, timber, masonry and aluminium in accordance with the test procedures specified in standards EN 13381-1-7”.

Safety measures

R = Stability

The ability of a building component to retain its mechanical strength when exposed to fire

E = Held

The ability of a building component to prevent the passage of, or the generation of, flames, vapours or hot gases on the unexposed side

I = Insulation

The ability of a building component to limit, within a specified limit, the transfer of heat from the opposite side to the one exposed

W (irradiation), M (mechanical action), C (durability of the closure), S (lock strength)

Load-bearing walls or beams (structures designed to withstand an applied load): REI requirement.
Non-load-bearing walls or fire doors (elements or structures not subject to any load other than their own weight): EI requirement.

There are many different materials that can be used, ranging from steel to wood; of course, from a structural point of view, wood remains the best material. As well as offering unrivalled aesthetic appeal, it is extremely flexible, lightweight and a poor conductor of heat.

Although flammable, the organic composition of wood remains the best protection in the event of a fire. In fact, surface charring acts as a barrier against flames and high temperatures.

Request a consultation with the experts at Renner Italia. We’ll find the right fire-retardant or intumescent solution for you.

This field is for validation purposes and should be left unchanged.